Summary

DOI: 10.1373/clinchem.2013.220467

A 33-year-old woman of Indian origin presented for prenatal care at term. An ultrasound report from earlier in her pregnancy indicated complete placenta previa and placenta increta, which were confirmed by repeat ultrasound. She was admitted to the hospital for monitoring and delivery planning.



Student Discussion

Student Discussion Document (pdf)

Mathew P. Estey,1,2* Gwen Clarke,3 Winnie Sia,4,5 Erinjit Toor,4 and Trefor N. Higgins1

1DynaLIFEDx, Alberta, Canada; 2Department of Laboratory Medicine and Pathology, University of Alberta; 3Royal Alexandra Hospital, University of Alberta; Departments of 4Medicine and 5Obstetrics and Gynecology, University of Alberta, Alberta, Canada.
*Address correspondence to this author at: DynaLIFEDx, #200, 10150-102 St., Edmonton, Alberta, Canada. Fax 780-4542845; e-mail [email protected].

Case Description

A 33-year-old woman of Indian origin presented for prenatal care at term. An ultrasound report from earlier in her pregnancy indicated complete placenta previa and placenta increta, which were confirmed by repeat ultrasound. She was admitted to the hospital for monitoring and delivery planning.

On admission, brown vaginal spotting was noted on the patient’s pad. Her nail beds and fingers were cyanotic, and a finger prick blood sample was rusty brown in appearance. Oxygen saturation by pulse oximetry on room air was 45% despite her appearing clinically well. She was otherwise asymptomatic. The patient’s husband remarked that her family has “brown blood, not red,” noting that the patient’s father, paternal grandfather, and sister also have brown blood but no clinical problems. Her 3-year-old daughter had a similar cyanotic appearance but was otherwise asymptomatic.

Repeat oxygen saturation measurements by pulse oximetry consistently gave results between 40%–60%, and arterial blood PO2 was 95 mmHg. Methemoglobin measurement was attempted, but the cooximeter indicated “?Oximetry measuring error.” This was also confirmed by repeated measurements.

Complete blood count results were as follows: hemoglobin, 12.5 g/dL (125 g/L; reference interval, 120–160 g/L); red blood cells (RBC), 4.19 × 1012/L (reference interval, 3.80 – 5.20 × 1012/L); hematocrit (HCT), 38% (0.38; reference interval, 0.36–0.46); mean corpuscular volume (MCV), 90 fL (reference interval, 80–100 fL); mean corpuscular hemoglobin (MCH), 30 pg (reference interval, 26–35 pg); mean corpuscular hemoglobin concentration (MCHC), 33.3 g/dL (333 g/L; reference interval, 310–360 g/L); red cell width distribution (RDW), 13.2% (reference interval, 15.6%); platelets (PLT), 224 × 109/L (reference interval, 140–450 × 109/L); white blood cells (WBC) 9.6 × 109/L (reference interval, 4.0 –11.0 × 109/L).

A peripheral blood film showed mild anemia with microcytes, no significant polychromasia or poikilocytosis, and neutrophils with prominent granulation. There was no increase in reticulocyte count, and glucose-6-phosphate dehydrogenase activity was normal.

The newborn child was also found to be cyanotic at birth, with brown blood similar to the mother’s. Attempts to measure methemoglobin were once again unsuccessful, and oxygen saturation results by pulse oximetry were consistently very low despite normal vital signs. Complete blood count results for the infant were as follows: hemoglobin, 17.2 g/dL (172 g/L; reference interval, 135–195 g/L); RBC, 4.66 ×1012/L (reference interval, 3.90 –5.50 × 1012/L); HCT, 51% (0.51; reference interval, 0.42– 0.60); MCV, 110 fL (reference interval, 98–118 fL); MCH, 37 pg (reference interval, 26–35 pg); MCHC, 33.5 g/dL (335 g/L; reference interval, 330–360 g/L); RDW, 16.0% (reference interval, <15.6%); PLT, 176 × 1012/L (reference interval, 140–450 × 109/L); WBC, 12.5 × 1012/L (reference interval, 9.0 –30.0 × 109/L).

Questions to Consider

  • What are causes of cyanosis and brown blood?
  • What additional laboratory tests could be useful in this case?
  • What could cause both the pulse oximeter and cooximeter to give unusual results?

Final Publication and Comments

The final published version with discussion and comments from the experts appears in the March 2015 issue of Clinical Chemistry, approximately 3-4 weeks after the Student Discussion is posted.

Educational Centers

If you are associated with an educational center and would like to receive the cases and questions 3-4 weeks in advance of publication, please email [email protected].

AACC is pleased to allow free reproduction and distribution of this Clinical Case Study for personal or classroom discussion use. When photocopying, please make sure the DOI and copyright notice appear on each copy.


DOI: 10.1373/clinchem.2013.220467
Copyright © 2015 American Association for Clinical Chemistry