A 33-year-old male patient visited the outpatient clinic at Brigham and Women's Hospital for a routine follow-up for obesity, obstructive sleep apnea, allergic rhinitis, and depression. He was maintained on a nocturnal continuous positive airway pressure device, loratadine, duloxetine, and fluticasone nasal spray. He was a resident of Boston and had not traveled outside the country. He denied intravenous drug use or high-risk sexual behavior, and he had not received any blood products. He had received his most recent influenza vaccine about 6 months earlier.


Student Discussion

Student Discussion Document (pdf)

Vinay S. Mahajan,1 Christine A. Pace,2 and Petr Jarolim1*

1Departments of Pathology and 2Internal Medicine, Brigham and Women’s Hospital, Boston, MA.
*Address correspondence to this author at: Department of Pathology, Brigham and Women’s Hospital, 75 Francis St., Boston, MA 02115. Fax 617-731-4872; e-mail [email protected].

3Nonstandard abbreviations: WB, western blot; NAT, nucleic acid testing.

Case Descriptions

A 33-year-old male patient visited the outpatient clinic at Brigham and Women’s Hospital for a routine follow-up for obesity, obstructive sleep apnea, allergic rhinitis, and depression. He was maintained on a nocturnal continuous positive airway pressure device, loratadine, duloxetine, and fluticasone nasal spray. He was a resident of Boston and had not traveled outside the country. He denied intravenous drug use or high risk sexual behavior, and he had not received any blood products. He had received his most recent influenza vaccine about 6 months earlier. He was screened for type 2 diabetes and hyperlipidemia. As a part of routine clinical care, he was also offered HIV screening in accordance with the current CDC recommendations (1). The HIV assay (HIV 1/O/2 Enhanced, EHIV), which was performed on the ADVIA Centaur analyzer (Siemens Healthcare Diagnostics), yielded a reactive result. As per the assay protocol developed by the manufacturer, the initially reactive sample was retested in duplicate after centrifugation; both results were reactive. The positive screen was followed up with a confirmatory western blot (WB)3 analysis, which yielded an indeterminate result. The presence of an isolated p24 band in the WB (GS Western HIV-1; Bio-Rad Laboratories) was of concern regarding possible early HIV seroconversion.

Questions to Consider

  • What factors are known to cause false-positive HIV serological test results?
  • What factors are known to cause an indeterminate WB results?
  • What further testing or clinical history would be of help in evaluating a patient with an indeterminate WB result?

Final Publication and Comments

The final published version with discussion and comments from the experts appears in the October 2010 issue of Clinical Chemistry, approximately 3-4 weeks after the Student Discussion is posted.

Educational Centers

If you are associated with an educational center and would like to receive the cases and questions 3-4 weeks in advance of publication, please email [email protected].

AACC is pleased to allow free reproduction and distribution of this Clinical Case Study for personal or classroom discussion use. When photocopying, please make sure the DOI and copyright notice appear on each copy.


DOI: 10.1373/clinchem.2009.139535
Copyright © 2010 American Association for Clinical Chemistry